Menu
必威app精装版下载
  • Home
  • 必威 备用网址
    • Pyranometers
    • 58biwei
    • Daily Light Integral Measurement
    • Infrared Radiometers
    • Aspirated Radiation Shield
    • 58必威
    • Net Radiometer
    • 58必威网站6
    • 58必威网站
    • 58必威网
    • 58必威外网
    • Oxygen Sensors
    • UV Sensors
    • Chlorophyll Concentration
    • Barometric Pressure
    • PAR Meters for Aquariums
    • microCache Bluetooth Micro Logger
    • Red - Far-red and PAR-FAR Sensors
    • Photometric Sensor
    • PRI Sensors
    • Solar Energy PV Monitoring
    • Accessories
    • Calibration Services
    • Replacement Cables
    • Refurbished Products
  • ABOUT US
    • Contact Us
    • International Distributors
    • Careers
    • Apogee News
    • Company History
    • Event Calendar
    • 工作人员清单
    • Apogee Cares
    • Our Founder - Dr. Bruce Bugbee
    • bob体育外网下载
    • Customer Satisfaction Survey
  • 必威亚洲体育品牌
  • Support
  • Sign In / Register
  • Search
  • International Distributors
  • My Cart(0)
    Your cart is empty

Field Spectroradiometer Support

Specifications
Videos
Case Studies
Product Manuals
Spec Sheets
Technical Drawings
Helpful Articles & Links
FAQs
Software & Datalogger Programs
Recalibration & Repair
Applications and Uses of Spectroradiometers

Field Spectroradiometer Specifications
Specifications Icon
SS-110 SS-120
Wavelength Range 340 to 820 nm 635 to 1100 nm
波长测量Interval 1 nm 1 nm
Wavelength Resolution 3 nm (full width half maximum) 3 nm (full width half maximum)
Wavelength Accuracy ± 0.5 nm ± 0.5 nm
Wavelength Repeatability ± 0.2 nm ± 0.2 nm
Analog to Digital Resolution 14 bit 14 bit
Signal to Noise Ratio 1500:1 (at maximum signal) 1500:1 (at maximum signal)
Stray Light ≤ 0.25 % at 590 nm ≤ 0.25 % at 850 nm
Dark Noise ≤ 3 counts ≤ 3 counts
Integration Time Range 10 ms to 10 s 10 ms to 10 s
Measurement Sensitivity Greater than 10 % of max sensitivity for wavelengths greater than 380 nm Greater than 10 % of max sensitivity for wavelengths greater than 1030 nm
Measurement Repeatability Less than 1 % (wavelengths greater than 400 nm) Less than 1 % (wavelengths greater than 1020 nm)
Directional (Cosine) Response ± 5 % at 75° zenith angle ± 5 % at 75° zenith angle
Fields of View 180° (upward-facing); 25° or 150° (downward-facing) 180° (upward-facing); 25° or 150° (downward-facing)
Temperature Response -0.1 ± 0.1 % per C -0.1 ± 0.1 % per C
Irradiance Calibration Uncertainty ± 5 % ± 5 %
电流消耗 190 mA (USB) 190 mA (USB)
Power Requirement 1 Watt (USB) 1 Watt (USB)
Interface Cable 5 m PVC jacket with USB (for computer) 5 m PVC jacket with USB (for computer)
Software Apogee Spectrovision (windows compatible, XP and later; Mac compatible 10.9 and later) Apogee Spectrovision (windows compatible, XP and later; Mac compatible 10.9 and later)
Operating Environment -20 to 70 C, 0 to 100 % relative humidity -20 to 70 C, 0 to 100 % relative humidity
Thread Size (for mounting) ¼-20 ¼-20
Dimensions 89.3 mm height, 50.8 mm width, 38.1 mm depth 89.3 mm height, 50.8 mm width, 38.1 mm depth
Mass 300 g 300 g

Field Spectroradiometer Videos
Videos Icon

Apogee Instruments Spectroradiometer

PAR, PPF, PPFD, and PFD Explained

Photobiology Simplified with Dr Bruce Bugbee

Lecture 8-Hyperspectral Reflectance

Lecture 4-PAR

Field Spectroradiometer Case Studies
Case Studies Icon
Typical Applications

Measurement of spectral output (energy flux density, photon flux density, or illuminance) of different radiation sources (often for plant or human lighting), and reflectance and transmittance measurements of natural and synthetic surfaces and materials (often plant leaves and canopies).

Supplemental Far-red Light Research of Foxglove Seedlings
Supplemental Far-red Light Research of Foxglove Seedlings
Determining the effect of far-red light on Foxglove Seedlings.
Read More >
PDF >
Reflectance Measurements in Cotton Fields
Reflectance Measurements in Cotton Fields
Estimating defoliation of cotton using reflectance data.
Read More >
Output of LED and Traditional Lamps
Output of LED and Traditional Lamps
PS-100 used to examine the output of several LED lamps and traditional lamps.
Read More >

If you would like to share your application of this product, pleaseclick here

Field Spectroradiometer Product Manuals
Product Manuals Icon
SS-110
SS-120

Field Spectroradiometer Specification Sheets
Specification Sheets Icon
SS-110
SS-120

Field Spectroradiometer Technical Drawings
Technical Drawings Icon
SS-110
SS-120

Helpful Articles and Links

Vegetation indices that can be calculated using the SS-110 for reflectance measurements

Field Spectroradiometer FOV Calculations

Journal Articles

Irradiance from Distinct Wavelength Light-emitting Diodes Affect Secondary Metabolites in Kale

Red and Far-red Insensitive 2, a Ring-Domain Zinc Finger Protein, Mediates Phytochrome-Controlled Seedling Deetiolation Responses

The Effect of Temperature, Photoperiod, and Light Quality on Gluconasturtiin Concentration in Watercress (Nasturtium officinale R. Br.)

Green Light Stimulates Early Stem Elongation, Antagonizing Light-Mediated Growth Inhibition

Photobiological Properties of the Inhibition of Etiolated Arabidopsis Seedling Growth by Ultraviolet-B Irradiation

Determination of Critical Oxygen Level in Packages for Cooed Sliced Ham to Prevent Color Fading During Illuminated Retail Display

Sources of Variability in Canopy Reflectance and the Convergent Properties of Plants

Field-based Phenomics for Plant Genetics Research

Preparation of a Low-cost Digital Camera System for Remote Sensing

Cuttings of Impatiens, Pelargonium, and Petunia Propagated under Light-emitting Diodes and High-pressure Sodium Lamps Have Comparable Growth Morphology, Gas Exchange, and Post-transplant Performance

Comparison of Supplemental Lighting from High-pressure Sodium Lamps and Light-emitting Diodes during Bedding Plant Seedling Production

Seasonal Variation in Glucosinolate Accumulation in Turnip Cultivars Grown with Colored Plastic Mulches

Far-red Light is needed for Efficient Photochemistry and Photosynthesis

FAQs
For FAQs Click Here

Didn't find your answer?

  1. Home
  2. /58必威
  3. /Field Spectroradiometers
  4. /Field Spectroradiometer Support

Shop by brand

  • Apogee
  • Campbell Scientifice
SS-110 Field Spec with included USB cable
Quick View

SS-110: Field Spectroradiometer-340 to 820 nm

SS-120 Field Spectroradiometer with USB cable
Quick View

SS-120: Field Spectroradiometer-635 to 1100 nm

Compare Products

Subscribe to Our newsletter

About Apogee Instruments, Inc.

Address:
721 West 1800 North
Logan, UT 84321
United States of America

Hours: Monday-Friday 8 AM- 5 PM MST

Main Line / Order Status: (435) 792-4700
or sales@apogeeinstruments.com

Technical Sales and Support: (435) 245-8012
or techsupport@apogeeinstruments.com

Purchase

  • 必威 备用网址
  • Product Catalog
  • Case Studies
  • International Distributors
  • 必威亚洲体育品牌

Support

  • Technical Support
  • Sales Support
  • Product Manuals
  • Recalibration & Repair
  • Downloads
  • Sign In / Register
  • Sitemap

Company

  • Contact Us
  • Company History
  • Apogee News
  • Event Calendar
  • Careers
©必威app精装版下载

Search in Apogee Instruments, Inc.

Cart Checkout
  • 必威 备用网址
    • Pyranometers
    • 58biwei
    • Daily Light Integral Measurement
    • Infrared Radiometers
    • Aspirated Radiation Shield
    • 58必威
    • Net Radiometer
    • 58必威网站6
    • 58必威网站
    • 58必威网
    • 58必威外网
    • Oxygen Sensors
    • UV Sensors
    • Chlorophyll Concentration
    • Barometric Pressure
    • PAR Meters for Aquariums
    • microCache Bluetooth Micro Logger
    • Red - Far-red and PAR-FAR Sensors
    • Photometric Sensor
    • PRI Sensors
    • Solar Energy PV Monitoring
    • Accessories
    • Calibration Services
    • Replacement Cables
    • Refurbished Products
  • About Us
    • Contact Us
    • International Distributors
    • Careers
    • Apogee News
    • Company History
    • Event Calendar
    • 工作人员清单
    • Apogee Cares
    • Our Founder - Dr. Bruce Bugbee
    • bob体育外网下载
    • Customer Satisfaction Survey
  • 必威亚洲体育品牌
  • Blog
  • Support
  • Account
    • Sign In / Register
    • Returns
更多信息